Download dei software
Per avvalervi nel modo migliore delle funzionalità di questo Sito Supporto, si consiglia di identificarvi.
Non esitate a creare il vostro conto se non l’avete già fatto. In qualsiasi momento, un clic su Il mio conto vi permetterà di modificare i ragguagli da voi forniti.
Il Gruppo Chauvin Arnoux si propone di fornirvi un efficace servizio on line; se desiderate inoltrarci le vostre osservazioni vi preghiamo di inviarci una mail a: support@Chauvin-Arnoux.com
19 risultato/i :
METRIX firmware for SCOPIX oscilloscopes
Firmware upgrade for the following oscilloscopes:
-MTX3x52 v1.x --> v1.07
-MTX3x52 v2.x --> v2.11
-MTX3x52 v3.x --> v3.05
-MTX3354 --> v3.05
-HandScope --> v1.05
-handscope B --->v2.01
- SCOPIX I: OX7042, OX7062, OX7102, OX7104 v1.0x --> v2.24
- SCOPIX II: OX7042, OX7062, OX7102, OX7104 v3.0x --> v3.24
- SCOPIX II: OX7202, OX7204 v4.0x --> v4.24
- SCOPIX III: v4.xx --> v4.24
- SCOPIX BUS: v5.xx --> v5.26
- OX6000 --> v1.09
- OX6000 II: OX6062, OX6202, OX6204 v2.x --> v2.24
UPDATE :
15/11/2024
NB: This upgrade does not concern the SCOPIX IV range.
Follow the recommendations in the file Instructions.pdf.
Installation:
To upgrade your oscilloscope, you must download the LoaderScope software.
The first time you execute the application, it will de-install the old version. You must then execute the program a second time to install the new version v3.2.
| instructions.pdf | Update: 28/11/2024 Language: Multilingual Version : V3.2 |
| loaderscope_v3.2.zip | Update: 28/11/2024 Language: Multilingual Version : V3.2 |
Firmware update FTV500
firmware version 1.22
New firmware version 1.22 for FTV500
This new version is compatible with the FTV500 V1.20 and higher embedded firmware version.
Firmware update
The update requires the presence of an inserted and mounted USB key (symbol present).
To proceed with the update, an "upgrade.bin" file corresponding to the updated version of the Firmware must be present on the key.
| upgrade.zip | Update 08/01/2025 language : multilingual version : 1.22 |
Firmware v1.12 for CA 6422 - CA 6424
Download the latest version of the firmware v1.12 for the CA 6422 and CA 6424 and benefit from all the latest improvements.
Here is the procedure for connecting the device to the PC :
Please find enclosed the new firmware.
- Unzip it,
- Connect the instrument to the PC,
- Run the .exe file,
- A pop-up window will open,
- The first line will show the instrument, click on the "program" icon...
Please note: the CA 6422 and CA 6424 are non-communicating products, so the instruction "connect the instrument to the PC" is a shortcut and requires a tool not supplied as standard with the product.
| ca_6422_6424_procedure_maj.pdf | CA 6422 - CA 6424 Reading before install |
| 642x_rev_1.12.zip | update : 10/2025 Firmware version : 1.12 |
Firmware update
Firmware update for the devices C.A 1110, C.A 1227, CA 1550, C.A 1246, C.A 1821, C.A 1822 and C.A 1823 in version v4.28
To update your product, first check your firmware (embedded software) version by pressing and holding the following two buttons: the center button + the MEM/REC button.
If your product has firmware version 1.xx or 2.xx, please download firmware version 2.xx.
If your product has firmware version 4.xx, please download the 4.xx firmware.
Embedded software update procedure
- Download the .bin file from our web site, then press and hold the MEM key and switch the instrument on by pressing the ON/OFF key. The instrument displays BOOT.
- Release the keys and the instrument displays COPY, indicating that it is ready to receive the new software.
- Connect the instrument to your PC using the USB cord provided.
- Copy the .bin file to the instrument as if were a USB key.
- When the copying is done, press the MEM key and the instrument displays LOAD, indicating that the software is being installed.
- When installation is done, the instrument displays PASS or FAIL according to whether or not the operation succeeded. If installation fails, download the software again and repeat the procedure.
- Then the instrument restarts normally.
CAUTION : After the firmware update, you will have to update the Bluetooth module.
| ca1110_firmware_v2.00.zip | Updated : 09/11/2017 Version : V2.00 |
| fw_ca1110_v4.28.zip | Updated : 21/10/2025 Version : V4.28 |
| ca1227_firmware_v2.00.zip | Updated : 09/11/2017 Version : V2.00 |
| fw_ca1227_v4.28.zip | Updated : 21/10/2025 Version : V4.28 |
| ca1246_firmware_v2.00.zip | Updated : 09/11/2017 Version : V2.00 |
| fw_ca1246_v4.28.zip | Updated : 21/10/2025 Version : V4.28 |
| ca1821_firmware_v2.00.zip | Updated : 09/11/2017 Version : V2.00 |
| fw_ca1821_v4.28.zip | Updated : 21/10/2025 Version : V4.28 |
| ca1822_firmware_v2.00.zip | Updated : 09/11/2017 Version : V2.00 |
| fw_ca1822_v4.28.zip | Updated : 21/10/2025 Version : V4.28 |
| ca1823_firmware_v2.00.zip | Updated : 09/11/2017 Version : V2.00 |
| fw_ca1823_v4.28.zip | Updated : 21/10/2025 Version : V4.28 |
| ca1550_firmware_v2.00.zip | Updated : 09/11/2017 Version : V2.00 |
| fw_ca1550_v4.28.zip | Updated : 21/10/2025 Version : V4.28 |
Bluetooth module update for version v4.28 firmware devices
Allows you to install the latest version of the Bluetooth module in the device.
CAUTION : The firmware version v4.28 must be installed on the device before this update.
In order to update the Bluetooth module, you have to follow the procedure as below :
- Download and unzip the file bt122_xxxx.zip and copy BT122_xxxx.bin into the device.
- Switch on the device and press Bluetooth button.
- Wait for one minute for the PASS/FAIL message.
- If PASS message appeared, the file BT122_xxxx.bin will be renamed as BT122_FW.bin and will have to remain on the device.
- The Bluetooth module is updated.
| bt122_ca1110.zip | Update 21/10/2025 |
| bt122_ca1227.zip | Update 21/10/2025 |
| bt122_ca1246.zip | Update 21/10/2025 |
| bt122_ca1550.zip | Update 21/10/2025 |
| bt122_ca1821.zip | Update 21/10/2025 |
| bt122_ca1822.zip | Update 21/10/2025 |
| bt122_ca1823.zip | Update 21/10/2025 |
Data Logger Transfer
Data Logger Transfer software allows you to pilot your loggers.
With the software Data Logger Transfer, you will be able to :
- Setup the instruments,
- Download and display the trends,
- Display real time values,
- Display data in curves or table,
- Export automatic reports in Word (.docx format),
- Export data into Dataview (.dvb files) or into Excel
Compatible with Windows 7, 8, 8.1,10 and 11
Attention: DataView is not provided with the software Data Logger Transfer
| data_logger_transfer_v2.2.0309.zip | Updated : November 2025 Language : Multilingual Version : v2.2.0309 |
Firmware update FTV500
firmware version 1.26
New firmware version 1.22 for FTV500
This new version is compatible with the FTV500 V1.20 and higher embedded firmware version.
FIRMWARE UPDATE
The update requires the presence of an inserted and mounted USB key (symbol present).
To proceed with the update, an "upgrade.bin" file corresponding to the updated version of the Firmware must be present on the key.
| upgrade_fw.zip | Update 07/11/2025 language : multilingual version : 1.26 |
MTT Machine Tester Transfer Software v2.0.10
MTT Machine Tester Link Software V2.0.10
The MTT software allows you to control the instrument and analyse the measurements made with your CA 6161 / CA 6163.
Main functions
The MTT software is a tool for:
Configuration of the instrument,
Downloading and viewing data in memory,
Generation of reports from the measurement data.
- Configuration of the instrument,
- Downloading and viewing data in memory,
- Generation of reports from the measurement data,
- Creating Auto Script(s)
- Creating Customized Visual Inspection(s)
The software is available in 6 languages: German, English, Spanish, French, Italian and Portuguese.
To install, extract the zip file into a single folder, then run the setup.
Minimum computer requirements:
Windows® 10 or later
4 GB RAM
10 GB of disk space
Microsoft Office® 2016 or later for viewing and editing docx reports.
Windows® and Office® are registered trademarks of Microsoft®.
| log.ct_.pl_.mtt_.v1.4.6.zip | Updated : 09/2024 Language : multilingual Version : 1.4.6 |
| 696824b00_log.ct_.pl_.mtt2_.v2.0.10.zip | Updated : 12/2025 Language : multilingual Version : 2.0.10 |
Firmware CA 8345 v1.20
Firmware for power and energy analyser CA 8345.
Latest version of Firmware for CA 8345. Click on the link below to download the file and unzip it.
You can update in several ways :
- Copy the update file " Q2-update " you downloaded to a USB key and insert it into the slot in the device.
- Copy the update file " Q2-update " you downloaded to an SD card and insert it into the slot in the device.
Turn off the device and then turn it on in his specific firmware update mode. See user’s manual §3.3.6
Languages : French, German, English, Spanish, Italian, Arabic, Hindi, Russian, Czech, Swedish, Danish, Korean, Thai, Dutch, Turkish, Norwegian, Vietnamese, Polish, Chinese, Finnish, Portuguese, Romanian.
| 696256j00_q2-update_1.12.zip | Updated 08/2024 Languages : Multilingual Version : 1.12 |
| q2-update.zip | Updated 01/2026 Languages : Multilingual Version : 1.20 |
PC Software : CAmReport
Software for thermogram analysis and automatic report creation
The CAmReport software is equipped with a very simple user interface for:
> Analysis of the thermograms with the following tools:
- Cursors (automatic display of the temperature at the point selected).
- Thermal profile (automatic display of the Min/Max/Avg temperatures on the line).
- A square or circle for area analysis
- Polygons and polylines for more accurate analysis of certain areas in the thermogram.
Results tables quickly and automatically display all the information/analysis tools on the thermogram.

> Recovery of voice comments or related measurements
> Automatic merging of the thermal and real images recorded simultaneously
> Automatic creation of reports for export in .pdf or .docx format.

Configuration required:
Windows 10/ Windows 11 :
850 MB RAM for 32-bit
2 G for 64-bit
NET Framework 4.0 minimum
System: Windows 10 and Windows 11
Language: Multilingual (15 languages including French, English, German, Spanish, Italian , Dutch, Polish, Romanian, Czech, simplified Chinese, Portuguese, Swedish, Finnish, Turkish, Korean)
Version: v2.3.0 compatible with camera model C.A 1950 & CA1954.
Contains automatic update
CAmReport crashing after the Windows update
A cumulative update was rolled out on December 13th 2022. This update is responsible for systematically crashing CAmReport during report previews.
This issue was addressed in out-of-band updates released January 31, 2023
Link to Microsoft's procedure and access to corrective updates:
| install_camreport_v2.2.5.exe | Updated : 13/04/2018 Languages : Multilingual (15 languages) Version : v2.2.5 |
| install_camreport_release_2.3.0.0.zip | Updated : 22/01/2026 Languages : Multilingual (15 languages) Version : v2.3.0 |
firmware PEL 11x V1.14
A new firmware version is available for the PEL112, PEL113, and PEL115.
This update includes the following new features:
• Fixes incompatibility with Mini94 clamp
Unzip the folder on your PC and launch the Flashup executable, select Logger and DSP, and finally launch Program
the device must not be added to PEL Transfer to prevent its configuration from being locked.
| loader_pel11x_1.14.zip | update : 02/2026 languages : multilingual |
PC Software : CAmReport AI
Thermographic analysis software equipped with Artificial Intelligence
Thermographic analysis software equipped with Artificial Intelligence
The CAmReport AI software is equipped with a very simple user interface for:
> Analysis of the thermograms with the following tools:
- Cursors (automatic display of the temperature at the point selected).
- Thermal profile (automatic display of the Min/Max/Avg temperatures on the line).
- A square or circle for area analysis
- Polygons and polylines for more accurate analysis of certain areas in the thermogram.
Results tables quickly and automatically display all the information/analysis tools on the thermogram.
.
> Recovery of voice comments or related measurements
> Automatic merging of the thermal and real images recorded simultaneously
> The AI assistant analyses the equipment and automatically fills in observations and recommendations from your image,saving you valuable time.
> Automatic creation of reports for export in .pdf or .docx format.

Configuration required:
Windows 11 :
850 MB RAM for 32-bit
2 G for 64-bit
NET Framework 4.0 minimum
System: Windows 11
Language: Multilingual (15 languages including French, English, German, Spanish, Italian , Dutch, Polish, Romanian, Czech, simplified Chinese, Portuguese, Swedish, Finnish, Turkish, Korean)
Version: v3.0.0.0 compatible with camera model C.A 1950 & CA1954.
| install_camreport_ai_3.0.0.0.exe | MUpdated : 03/2026 Languages : Multilingual (15 languages) Version : v3.0.0.0 |
MTT2 Machine Tester Transfer Software v2.1.3
MTT Machine Tester Link Software V2.1.3
The MTT software allows you to control the instrument and analyse the measurements made with your CA 6161 / CA 6163.
Main functions
The MTT software is a tool for:
Configuration of the instrument,
Downloading and viewing data in memory,
Generation of reports from the measurement data.
- Configuration of the instrument,
- Downloading and viewing data in memory,
- Generation of reports from the measurement data,
- Creating Auto Script(s)
- Creating Customized Visual Inspection(s)
The software is available in 6 languages: German, English, Spanish, French, Italian and Portuguese.
To install, extract the zip file into a single folder, then run the setup.
Minimum computer requirements:
Windows® 10 or later
4 GB RAM
10 GB of disk space
Microsoft Office® 2016 or later for viewing and editing docx reports.
Windows® and Office® are registered trademarks of Microsoft®.
| 696824d00_log.ct_.pl_.mtt2_.v2.1.2.exe | Updated : 03/2026 Language : multilingual Version : 2.1.2 |
| 696824e00_log.ct_.pl_.mtt2_.v2.1.3.exe | Updated : 07/2026 Language : multilingual Version : 2.1.3 |
Firmware update CA 6161 - CA 6163 v 2.0.8
You will find hereafter an important firmware update for CA 6161 / CA 6163 instruments.
The attached procedure (file readme.pdf) describes how to update the CA 6161 / CA 6163 instruments while using MTT software
| 696268n_fw616x_v0.2.02_usemtt.zip | Updated April 2025, languages: multilingual Version : 2.0.2 |
| 696268r_fw616x_v0.2.08_usemtt.zip | Updated June 2026, languages: multilingual Version : 2.0.8 |
PAT 3 Software v1.8 & Samples
The PAT 3 Software - Power Analyser Transfer allows you to control your CA 8345 energy analyser.
To download this software, please click on the entilted file "x05077j00_pat3_1.8.zip" and unzip it. After that, double click on the "Setup.exe" to install it.
The PAT 3 Software is a tool for :
- Configure your CA 8345,
- Download and view data in memory,
- Make instantaneous acquisitions,
- Display the data in tabular or graphical form,
- Export measurement data to DataView (*.dvb files) or to a spreadsheet.
Once the PAT 3 software is installed, you can download the samples below which are available to you. To do this, download the file and unzip it. Once you have done this, save the file to /DataView/DataFiles/Qualistar Class A.
Recordings samples are :
- Trends
- Alarms
- Configuration
- Inrush
- Monitoring
- Photos
- Transcients
| pack_sample_pat3.zip | update 11/2022 |
| x05077j00_pat3_1.8.zip | Updated : 06/2026 Language : Multilingual Version : 1.8 |
Firmware CA 8345 v1.22
Firmware for power and energy analyser CA 8345.
Latest version of Firmware for CA 8345. Click on the link below to download the file and unzip it.
You can update in several ways :
- Copy the update file " Q2-update " you downloaded to a USB key and insert it into the slot in the device.
- Copy the update file " Q2-update " you downloaded to an SD card and insert it into the slot in the device.
Turn off the device and then turn it on in his specific firmware update mode. See user’s manual §3.3.6
Languages : French, German, English, Spanish, Italian, Arabic, Hindi, Russian, Czech, Swedish, Danish, Korean, Thai, Dutch, Turkish, Norwegian, Vietnamese, Polish, Chinese, Finnish, Portuguese, Romanian.
| 696256m00_q2-update_1.22.zip | Updated 06/2026 Languages : Multilingual Version : 1.22 |
Firmware update CA 6161 - CA 6163 v 2.0.8
You will find hereafter an important firmware update for CA 6161 / CA 6163 instruments.
The attached procedure (file readme.pdf) describes how to update the CA 6161 / CA 6163 instruments while using MTT software
Firmware upgrade using USB key
Installing updates requires a computer with internet connection and a USB storage device with at least 200 Mo of disk space.
Download the update file .zip
- Decompress file on USB storage device formatted in FAT32 at the root of the USB key.
- Switch off the device.
- Insert USB storage device on one of the two USB port of the device.
- Press the START/STOP button and switch on the device.
- After a few seconds, the update screen appears. Release the START STOP button.
- Wait until the update finish.
- Switch off the device
- Remove the USB storage
| 696268n_fw616x_v0.2.02_usemtt.zip | Mise à jour Juin 2025, langues: multilangues Version : 2.0.2 |
| 696268r_fw616x_v0.2.08_usemtt.zip | Updated June 2026, languages: multilingual Version : 2.0.8 |
PC software CAmReport AI
Thermographic analysis software equipped with Artificial Intelligence
Thermographic analysis software equipped with Artificial Intelligence
The CAmReport AI software is equipped with a very simple user interface for:
> Analysis of the thermograms with the following tools:
- Cursors (automatic display of the temperature at the point selected).
- Thermal profile (automatic display of the Min/Max/Avg temperatures on the line).
- A square or circle for area analysis
- Polygons and polylines for more accurate analysis of certain areas in the thermogram.
Results tables quickly and automatically display all the information/analysis tools on the thermogram.
.

> Recovery of voice comments or related measurements
> Automatic merging of the thermal and real images recorded simultaneously
> The AI assistant analyses the equipment and automatically fills in observations and recommendations from your image,saving you valuable time.
> Automatic creation of reports for export in .pdf or .docx format.

Configuration required:
Windows 11 :
850 MB RAM for 32-bit
2 G for 64-bit
NET Framework 4.0 minimum
System: Windows 11
Language: Multilingual (15 languages including French, English, German, Spanish, Italian , Dutch, Polish, Romanian, Czech, simplified Chinese, Portuguese, Swedish, Finnish, Turkish, Korean)
Version: v3.3.1.0 compatible with camera model C.A 1950 & CA1954.
| camreport_ai_3.3.1.0.zip | Updated : 06/2026 Languages : Multilingual (15 languages) Version : v3.3.1.0 |
PAT-Power Analyser Transfer
The PAT software is a tool for:
- Configuring the instruments,
- Downloading and viewing the data stored in the memory,
- Performing instantaneous acquisition operations,
- Displaying the data as a table or graph,
- Exporting the measurement data into DataView (*.dvb files) or into a spreadsheet.
For CA 8220/8230 CA 8332/32B/34/34B, CA8335/8435 (firmware versions v3.x) and F407 F607 use PAT, the main changes on PAT are :
- bugs fixed.
For CA 8331/33/36, CA 8436 et CA8335 (firmware version v4.x) use PAT2, the main changes on PAT2 are :
- added new language bulgarian
- bugs fixed.
Caution: DataView is not supplied with the PAT/PAT2 softwares
| pat-v3.08.0018.zip | Updated : Nov 2019 Language : Multilingual Version : v3.08.0018 |
| pat2_v1.8.16142.zip | Updated : June 2026 Language : Multilingual Version : v1.8.16142 |