Calibration in COFRAC-accredited laboratories
Manumesure benefits from laboratories with COFRAC accreditation for "Calibration"
The scopes of our 8 accreditations are available at www.cofrac.fr
All our measurements have guaranteed traceability to the national standards.
Quantities measured with COFRAC accreditation in our laboratories
Electricity & Magnetism
MANUMESURE laboratory at Pont-l’Evêque (France)
COFRAC accreditation for "Calibration" no. 2-1035
MANUMESURE laboratory at Annecy (France)
COFRAC accreditation for "Calibration" no. 2-1405
Voltage, Current, Resistance, Capacitance, Power & Energy
DC voltage: 1 μV to 30 kV
AC voltage: 1 mV to 15 kV
DC current: 1 μA to 1,000 A
AC current: 10 μA to 1,500 A
DC resistance: 10 μΩ to 1 TΩ
AC resistance: 0.1 Ω to 10 kΩ
Capacitance: 1 pF to 1 μF
Single and three-phase power: 100 mA to 10 A at 57.7 V - 100 V - 230 V
Single and three-phase energy: 100 mA to 10 A at 57.7 V - 100 V - 230 V
Time & Frequency
MANUMESURE laboratory at Annecy (France)
COFRAC accreditation for "Calibration" no. 2-1406
New COFRAC accreditation for Calibration of centrifuges: rotation speed & time
Frequency, Time & Rotation Speed
Frequency: 1 mHz to 26.5 GHz
Time: 1 μs to 1,000 s
Rotation speed: 6 to 60,000 RPM
Temperature
MANUMESURE laboratory at Pont-l’Evêque (France)
COFRAC accreditation for "Calibration" no. 2-1336
PYROCONTROLE laboratory at Lyon (France)
COFRAC accreditation for "Calibration" no. 2-1385
MANUMESURE also performs on-site calibration of Pt 100 temperature sensors, from - 25 °C to + 150 °C
Platinum Resistance & Thermocouple
Platinum resistance: - 80 °C to + 500 °C
Thermocouple: - 80 °C to + 1,500 °C
Pressure
MANUMESURE laboratory at Lyon (France)
COFRAC accreditation for "Calibration" no. 2-1615
Relative gas pressure
Relative gas pressure: 0 to 2.5 MPa
Micropipettes
MANUMESURE laboratory at Lyon (France)
COFRAC accreditation for "Calibration" no. 2-1913
Volume of micropipettes
Volume: 2.5 μl to 10 ml
Dimensions
MANUMESURE laboratory at Pont-l’Evêque (France)
COFRAC accreditation for "Calibration" no. 2-1310
The Pont l’Evêque laboratory is also equipped with a three-dimensional machine for checking parts on the basis of drawings.
Lengths, diameters & threads
Gauge block L: 0.5 to 500 mm
Gauge rod L: 0.1 to 20 mm
Plug gauge Ø: 20 to 200 mm
Thread plug gauge Ø: 1.6 to 100 mm
Plain ring gauge Ø: 2 to 200 mm
Vernier calliper L: 0 to 1,000 mm
Depth slide gauge L: 0 to 600 mm
Outside screw micrometer L: 0 to 200 mm
Mechanical comparator L: 0 to 30 mm
Spindle L: 25 to 600 mm
Electronic comparator L: 0 to 100 mm