With a C.A 43, which measured values are closest to reality: measurements with or without the PEAK function?
Response
Answered on
7/16/14
The PEAK mode can be used to measure rapid variations in electric fields, whereas the standard mode is more representative of humans' exposure to electric fields and is therefore used most of the time.