CA 8436 Three-phase analyser Power Energy IP67
IP67 (4I/4U) graphical analyser of power, energy, harmonics and three-phase disturbances CA8436 - Campaigns EN50160
The CA 8345 is a Class A Qualistar power and energy quality analyser.
Like the Qualistar+ models, it is equipped with an intuitive HMI and remains simple to use. Multilingual online help can be displayed at any time on the large LCD colour touch screen. A virtual keyboard is available in all modes and is displayed automatically on the HMI as soon as input is required to: - lock the configuration with a password - type emails directly
Easy to handle, it is intended for inspection and maintenance teams working on industrial or tertiary installation. I can be used to obtain a snapshot of the main power quality parameters. The Qualistars can be used on any type of installation. For greater safety, the CA 8345 automatically recognizes the type of current sensor connected. The CA 8345 offers high measurement accuracy. It proposes numerous calculated values and several processing functions. It offers users all the measurements required for successful energy efficiency projects and electrical distribution monitoring. It is also possible to immediately find out the value of the electricity consumed by means of an electricity cost calculation. The CA 8345 can display harmonics and interharmonics as required by IEC 61000-4-7 up to the 127th order. At the same time, it detects the carrier currents flowing on the installation. Flicker measurements are performed according to the IEC 61000-4-15 standard. The CA 8345 monitors all the events on the network:
A Monitoring mode can be used to record measurement campaigns for analysis according to EN50160.
Communication In addition to SD cards and USB drives, it is possible to recover the measurements and communicate remotely with the CA 8345 using USB, remote links, Wifi (direct WAP or via server) or RJ45. An IRD server mode allows data extraction from anywhere in the world without threatening the security of the internet network. The Power Analyser Transfer PAT3 software can be used to process the measurements made with the Qualistar Class A. It can be downloaded from our support site. The Qualistar CA 8345 is certified as compliant with Class A of the IEC 61000-4-30 ed4 standard
See the certificate IEC 62586 standard used for certification.
Electrical safety
Software
Recycling criteria
Communication mode
Designed and manufactured
Guarantee
Standard
Protection class
Standard com and prog
Communication interface
Real effective measurement
Load start measurement
USB communication mode
Secure remote connection
WiFi communication mode
Need information about our solutions? Our experts are available to advise and assist you with your project. Contact a sales representative now for a detailed presentation and an offer tailored to your needs.
Inputs
Isolated voltage/current
Voltage
Up to 1000 VAC DC
IEC 61000-4-30 (Ed 4)
Class A (Full)
Screen
7' color touch LCD: 800 x 480 (WVGA)
Battery cartridge
Li-ion / 8 hours autonomy
Real-time mode
Yes
Sampling
400 ksps in voltage and 200 ksps in current
Power mode
Yes
Energy mode
Yes
Unbalance mode
Composite
Harmonic mode
from DC to rank 127
Inter-harmonic mode
from 0 to rank 62
Trend recording
> 900 parameters
Harmonic phase recording
Yes
Alarm mode (type / number)
40 / 20,000
Carrier current detection mode
Yes
Inrush capture
100
Transient (number)
No maximum (SD card)
Shock waves
Up to 12 kV for a duration of 500 ns @ 2 Msps
EN50160 monitoring mode
With PAT3 software
USB communication
Yes
SD card
Externally accessible
Ethernet
Yes
Wifi
Yes
Webserver
Yes
USB key port (Type A)
Yes
Wide range of current sensors
See Qualistar accessories
IEC 61010 safety
CAT IV 1000V
Protection
IP54
Temperature
[+0 °C ; +40 °C]
Environmental conditions
IEC 61557-12 & IEC 62586
Dimensions (H x L x E)
200x285x55 mm / 1.9 kg
Warranty
3 years
Language *
Do you have a question about using or installing your measurement equipment? Our support team is available to provide you with quick and effective solutions. Contact support for personalized assistance.
Language *
Do you have a question about using or installing your measurement equipment? Our support team is available to provide you with quick and effective solutions. Contact support for personalized assistance.
Language *
Do you have a question about using or installing your measurement equipment? Our support team is available to provide you with quick and effective solutions. Contact support for personalized assistance.
Click on the link below to download the file and unzip it.
There are several ways to carry out the update:
Languages: French, German, English, Spanish, Italian, Arabic, Hindi, Russian, Czech, Swedish, Danish, Korean, Thai, Dutch, Turkish, Norwegian, Vietnamese, Polish, Chinese, Finnish, Portuguese, Romanian
To download this software, please click on the file named ‘x05077h00_pat3_1.8.zip’ and then extract it. Once this is done, double-click on ‘Setup.exe’ to install it.
The PAT 3 software is a tool that allows you to:
Once the PAT 3 software is installed, you can download the “Sample” files below, which are available for your use. To do this, download the file and then unzip it. Once this is done, save the file to /DataView/DataFiles/Qualistar Class A.
The sample records are files:
SCPI order booklet for the CA 8345 so that you can integrate your product in a system. It will enable your system's software to control your CA 8345 remotely.
The Data® software is an essential tool for configuring, initiating measurements, viewing data in real time, retrieving recorded data and creating standard or customised measurement reports.
It constitutes a single software platform for operating the majority of Chauvin Arnoux products, including:
Easy to use, the Data® software automatically recognises the device connected to the PC, allowing the user to access the data stored in the device, its settings and real-time data directly.
Data® automatically generates measurement reports or creates new customised reports on demand. Finally, this tool offers numerous additional functions for the user’s convenience or for more in-depth analysis: zooming in on graphs to analyse specific sections on display; on-demand display of various recorded parameters; exporting the displayed data to Excel; linking and integrating objects (OLE), etc.
Data allows address details for customers, work sites, etc. – extracted from a database – to be automatically linked to measurement reports. The devices connect to the PC via USB, RS232, Wi-Fi or Bluetooth, depending on the model.
DataView is available in the following languages: German, English, Chinese, Spanish, French, Italian, Dutch, Polish, Swedish, Czech and Turkish.
Do you have a question about using or installing your measurement equipment? Our support team is available to provide you with quick and effective solutions. Contact support for personalized assistance.
To fully meet your expectations, a range of accessories is available that is compatible with your equipment. Feel free to add them to your quote request to obtain a complete and tailored solution.
P01160657N
CA8345 (4I/4U) graphical analyser of three-phase power, energy, harmonics and disturbances. IEC61000-4-30 Class A - EN50160 campaigns
P01102095
PC software for configuring, saving and processing data, editing reports, etc. for Chauvin Arnoux measuring instruments
P01103076
PA32ER mains adaptor up to 1000V AC and DC to supply the voltage measurement channels of Qualistar2 CA8345 units
P01102155
50VA mains adapter to power the Qualistar CA8345 and Scopix IV
P01103077
Adapter with C8 type input connector and output on 2 x 4 mm banana plugs, spaced 19 mm apart
P01295174
2P mains power cord / shaver plug for power supply via a 2-pole socket
P01298083
Carrying case for Chauvin Arnoux Qualistar2 power quality analysers CA834x
P01103078
16 GB 30 MB/second Class 10 SD-HC memory card for Qualistar2 CA8345 units
P01103079
Magnetic hook for CA8345
P01295531
HX0122
Adjustable carrying strap for SCOPIX IV oscilloscope
P01102130
Passive charging support Li-Ion battery pack for CA 6116N, CA 6117, requires mains adapter / type 2 charger P01102129 and requires mains lead P01295174
P01296047
Spare battery 5.8Ah for low-voltage installation controller CA 6116, CA 6117
P01120323B
AC current clamp - Current range 1A to 1000A - Clamping diameter 52 mm - For Qualistar and PEL power loggers
P01120425B
AC current clamp - Current range 500mA to 200A - Clamping diameter 20 mm - For Qualistar and PEL power loggers
P01120434B
AC current clamp - 2 current ranges 5mA to 100A - 20 mm clamping diameter - For Qualistar and PEL power recorders
P01120044
AC-DC current clamp - Current range 100mA 100A - 2 ratings 10A and 100A - Clamping diameter 11.8 mm - For Qualistar2 and PEL power recorders
P01120079B
AC-DC current clamp - 1A to 1000A current range - 39 mm clamping diameter - For CA82xx - CA833x - CA 843x - PEL power loggers
P01101967
Mains adapter 230V 50/60 Hz European plug 2P for PAC series AC/DC current meters
P01101959
5A current adaptor for TI output 3-phase banana plugs for Qualistar QualistarPlus and Qualistar2 CA833x & CA834x and PEL
P01102131
ESSAILEC-type adapter box for current inputs for CA82xx - CA833x - CA843x - PEL10x - PEL11x power analysers and recorders
P01120110
AC-DC current clamp - Current range 50-3500 Aac - 50-5000 Adc for CA833x - CA843x - PEL10x
P01120526B
Flexible AC current sensor - Current range 100mA to 10000A - Diameter 140mm - For Qualistar and PEL power loggers
P01120531B
Flexible AC current transducer - Current range 100mA to 10000A - Diameter 250mm - For Qualistar and PEL power loggers
P01120593
Flexible AC current transducer - Current range 100mA to 10000A - Diameter 70mm - For Qualistar and PEL power loggers
P01120592
Flexible AC current sensor - Current range 100mA to 10000A - Diameter 100mm - For Qualistar and PEL power loggers
P01120594
Flexible AC current transducer - Current range 100mA to 10000A - Diameter 300mm - For Qualistar and PEL power loggers
P01102149
Reeling Box storage accessory for tangle-free voltage cables. Integrated magnet for easy attachment to any metal surface.
P01295483
Set of 5 cords of 3m - Banana-Banana straight 4mm - 5 crocodile clips - set of colour-coded markers
HX0061
Voltage converter from 10-60V DC 4A cigarette-lighter socket to 2P+T 120-150V DC 32W max female connector
P01106194
AC amperometric clamp - Current range 50mA to 200A AC - Clamping diameter 16 mm - For Qualistar2 and PEL power recorders
P01160658N
CA8345 (4I/4U) graphical analyser of power, energy, harmonics and three-phase disturbances. IEC61000-4-30 Class A - Campaigns EN50160 - With mains adaptor for measurement channels
P01120044
AC-DC current clamp - Current range 100mA 100A - 2 ratings 10A and 100A - Clamping diameter 11.8 mm - For Qualistar2 and PEL power recorders
P01102095
PC software for configuring, saving and processing data, editing reports, etc. for Chauvin Arnoux measuring instruments
P01103076
PA32ER mains adaptor up to 1000V AC and DC to supply the voltage measurement channels of Qualistar2 CA8345 units
P01102155
50VA mains adapter to power the Qualistar CA8345 and Scopix IV
P01103077
Adapter with C8 type input connector and output on 2 x 4 mm banana plugs, spaced 19 mm apart
P01295174
2P mains power cord / shaver plug for power supply via a 2-pole socket
P01298083
Carrying case for Chauvin Arnoux Qualistar2 power quality analysers CA834x
P01103078
16 GB 30 MB/second Class 10 SD-HC memory card for Qualistar2 CA8345 units
P01103079
Magnetic hook for CA8345
P01295531
HX0122
Adjustable carrying strap for SCOPIX IV oscilloscope
P01102130
Passive charging support Li-Ion battery pack for CA 6116N, CA 6117, requires mains adapter / type 2 charger P01102129 and requires mains lead P01295174
P01296047
Spare battery 5.8Ah for low-voltage installation controller CA 6116, CA 6117
P01120323B
AC current clamp - Current range 1A to 1000A - Clamping diameter 52 mm - For Qualistar and PEL power loggers
P01120425B
AC current clamp - Current range 500mA to 200A - Clamping diameter 20 mm - For Qualistar and PEL power loggers
P01120434B
AC current clamp - 2 current ranges 5mA to 100A - 20 mm clamping diameter - For Qualistar and PEL power recorders
P01106194
AC amperometric clamp - Current range 50mA to 200A AC - Clamping diameter 16 mm - For Qualistar2 and PEL power recorders
P01120079B
AC-DC current clamp - 1A to 1000A current range - 39 mm clamping diameter - For CA82xx - CA833x - CA 843x - PEL power loggers
P01101967
Mains adapter 230V 50/60 Hz European plug 2P for PAC series AC/DC current meters
P01101959
5A current adaptor for TI output 3-phase banana plugs for Qualistar QualistarPlus and Qualistar2 CA833x & CA834x and PEL
P01102131
ESSAILEC-type adapter box for current inputs for CA82xx - CA833x - CA843x - PEL10x - PEL11x power analysers and recorders
P01120110
AC-DC current clamp - Current range 50-3500 Aac - 50-5000 Adc for CA833x - CA843x - PEL10x
P01120526B
Flexible AC current sensor - Current range 100mA to 10000A - Diameter 140mm - For Qualistar and PEL power loggers
P01120531B
Flexible AC current transducer - Current range 100mA to 10000A - Diameter 250mm - For Qualistar and PEL power loggers
P01120593
Flexible AC current transducer - Current range 100mA to 10000A - Diameter 70mm - For Qualistar and PEL power loggers
P01120592
Flexible AC current sensor - Current range 100mA to 10000A - Diameter 100mm - For Qualistar and PEL power loggers
P01120594
Flexible AC current transducer - Current range 100mA to 10000A - Diameter 300mm - For Qualistar and PEL power loggers
P01102149
Reeling Box storage accessory for tangle-free voltage cables. Integrated magnet for easy attachment to any metal surface.
P01295483
Set of 5 cords of 3m - Banana-Banana straight 4mm - 5 crocodile clips - set of colour-coded markers
HX0061
Voltage converter from 10-60V DC 4A cigarette-lighter socket to 2P+T 120-150V DC 32W max female connector