Product presentation

The CA 8345 is a Class A Qualistar power and energy quality analyser.

Like the Qualistar+ models, it is equipped with an intuitive HMI and remains simple to use. Multilingual online help can be displayed at any time on the large LCD colour touch screen. A virtual keyboard is available in all modes and is displayed automatically on the HMI as soon as input is required to: - lock the configuration with a password - type emails directly

Easy to handle, it is intended for inspection and maintenance teams working on industrial or tertiary installation. I can be used to obtain a snapshot of the main power quality parameters. The Qualistars can be used on any type of installation. For greater safety, the CA 8345 automatically recognizes the type of current sensor connected. The CA 8345 offers high measurement accuracy. It proposes numerous calculated values and several processing functions. It offers users all the measurements required for successful energy efficiency projects and electrical distribution monitoring. It is also possible to immediately find out the value of the electricity consumed by means of an electricity cost calculation. The CA 8345 can display harmonics and interharmonics as required by IEC 61000-4-7 up to the 127th order. At the same time, it detects the carrier currents flowing on the installation. Flicker measurements are performed according to the IEC 61000-4-15 standard. The CA 8345 monitors all the events on the network:

  • Trend diagram, variations of the signal parameters
  • Configurable alarms, with the possibility of sending users email alerts
  • 2.5 µs transients
  • 12 kV shockwaves lasting 500 ns
  • TrueInrush, with a pre-trigger, to capture the startups of all the loads….

A Monitoring mode can be used to record measurement campaigns for analysis according to EN50160.

Communication In addition to SD cards and USB drives, it is possible to recover the measurements and communicate remotely with the CA 8345 using USB, remote links, Wifi (direct WAP or via server) or RJ45. An IRD server mode allows data extraction from anywhere in the world without threatening the security of the internet network. The Power Analyser Transfer PAT3 software can be used to process the measurements made with the Qualistar Class A. It can be downloaded from our support site. The Qualistar CA 8345 is certified as compliant with Class A of the IEC 61000-4-30 ed4 standard

See the certificate IEC 62586 standard used for certification.

See the documents available in other languages

Electrical safety

Electrical safety

Software

Software

Recycling criteria

Recycling criteria

Communication mode

Communication mode

Designed and manufactured

Designed and manufactured

Guarantee

Guarantee

Standard

Standard

Protection class

Protection class

Standard com and prog

Standard com and prog

Communication interface

Communication interface

Real effective measurement

Real effective measurement

Load start measurement

Load start measurement

USB communication mode

USB communication mode

Secure remote connection

Secure remote connection

WiFi communication mode

WiFi communication mode

Need information about our solutions? Our experts are available to advise and assist you with your project. Contact a sales representative now for a detailed presentation and an offer tailored to your needs.


Contact a sales representative

Highlights

  • Voltage quality diagnostics
  • Full compliance with IEC 61000-4-30 Class A Ed 4
  • Highly communicating instrument
  • Qualistar range of easy-to-use products
  • Alarms, recordings, transients, Inrush, etc.

Features

Inputs

Isolated voltage/current

Voltage

Up to 1000 VAC DC

IEC 61000-4-30 (Ed 4)

Class A (Full)

Screen

7' color touch LCD: 800 x 480 (WVGA)

Battery cartridge

Li-ion / 8 hours autonomy

Real-time mode

Yes

Sampling

400 ksps in voltage and 200 ksps in current

Power mode

Yes

Energy mode

Yes

Unbalance mode

Composite

Harmonic mode

from DC to rank 127

Inter-harmonic mode

from 0 to rank 62

Trend recording

> 900 parameters

Harmonic phase recording

Yes

Alarm mode (type / number)

40 / 20,000

Carrier current detection mode

Yes

Inrush capture

100

Transient (number)

No maximum (SD card)

Shock waves

Up to 12 kV for a duration of 500 ns @ 2 Msps

EN50160 monitoring mode

With PAT3 software

USB communication

Yes

SD card

Externally accessible

Ethernet

Yes

Wifi

Yes

Webserver

Yes

USB key port (Type A)

Yes

Wide range of current sensors

See Qualistar accessories

IEC 61010 safety

CAT IV 1000V

Protection

IP54

Temperature

[+0 °C ; +40 °C]

Environmental conditions

IEC 61557-12 & IEC 62586

Dimensions (H x L x E)

200x285x55 mm / 1.9 kg

Warranty

3 years

Documentation and support

Do you have a question about using or installing your measurement equipment? Our support team is available to provide you with quick and effective solutions. Contact support for personalized assistance.


Contact support

Do you have a question about using or installing your measurement equipment? Our support team is available to provide you with quick and effective solutions. Contact support for personalized assistance.


Contact support

Do you have a question about using or installing your measurement equipment? Our support team is available to provide you with quick and effective solutions. Contact support for personalized assistance.


Contact support

Click on the link below to download the file and unzip it.

There are several ways to carry out the update:

  • Copy the ‘Q2-update’ update file from the compressed file you downloaded onto a USB stick and insert it into the device’s port.
  • Copy the ‘Q2-update’ file that you have downloaded onto an SD card and insert it into the device’s port.
  • Switch the device off, then switch it back on in the specific firmware update mode. See the user manual, section 3.3.6

Languages: French, German, English, Spanish, Italian, Arabic, Hindi, Russian, Czech, Swedish, Danish, Korean, Thai, Dutch, Turkish, Norwegian, Vietnamese, Polish, Chinese, Finnish, Portuguese, Romanian

To download this software, please click on the file named ‘x05077h00_pat3_1.8.zip’ and then extract it. Once this is done, double-click on ‘Setup.exe’ to install it.

 

The PAT 3 software is a tool that allows you to:

  • Configure your CA 8345,
  • Download and view data in memory,
  • Take instantaneous measurements,
  • Display data as tables or graphs,
  • Export this measurement data to DataView (*.dvb files) or to a spreadsheet.

Once the PAT 3 software is installed, you can download the “Sample” files below, which are available for your use. To do this, download the file and then unzip it. Once this is done, save the file to /DataView/DataFiles/Qualistar Class A.

The sample records are files:

  • Trends
  • Alarms
  • Configuration
  • Inrush
  • Monitoring
  • Photos
  • Transients

SCPI order booklet for the CA 8345 so that you can integrate your product in a system. It will enable your system's software to control your CA 8345 remotely.

DataView® is a paid ‘logical’ platform common to all products, enabling advanced analyses. However, each product has its own Control Panel (which is free to use) for carrying out simple analyses. These Control Panels can be downloaded from the relevant product’s web page or from the Support section of the website.

 

The Data® software is an essential tool for configuring, initiating measurements, viewing data in real time, retrieving recorded data and creating standard or customised measurement reports.

It constitutes a single software platform for operating the majority of Chauvin Arnoux products, including:

  • QualiStar energy analysers CA 8331, CA 8333, CA 8336, CA 8436, CA 8345
  • Power controllers CA 8220, CA 8230
  • Power and energy loggers PEL51, PEL52, PEL102, PEL103, PEL105, PEL104, PEL 106, PEL112, PEL113 & PEL 115
  • Earth testers CA 6470N, CA 6471, CA 6472
  • Insulation testers CA 6543, CA 6547, CA 6549, CA 6550, CA 6555, CA 6526, CA 6532 & CA 6534
  • Clamp meters F407, F607
  • The SIMPLE LOGGER 2 range of data loggers
  • CA 6417 earth clamps
  • CA 6116N and CA 6117 multifunction installation testers
  • DTR8510 and DTR8511 ratio meters
  • CA 1821, CA 1822 & CA 1823 thermometers
  • CA 1246 thermo-hygrometer
  • CA 1227 thermo-anemometer
  • CA 1110 lux meter
  • CA 10101 pH meter
  • CA 10141 conductivity meter
  • CA 1510 air quality analyser
  • Current and voltage recorders L411, L412 and L461

Easy to use, the Data® software automatically recognises the device connected to the PC, allowing the user to access the data stored in the device, its settings and real-time data directly.

Data® automatically generates measurement reports or creates new customised reports on demand. Finally, this tool offers numerous additional functions for the user’s convenience or for more in-depth analysis: zooming in on graphs to analyse specific sections on display; on-demand display of various recorded parameters; exporting the displayed data to Excel; linking and integrating objects (OLE), etc.

Data allows address details for customers, work sites, etc. – extracted from a database – to be automatically linked to measurement reports. The devices connect to the PC via USB, RS232, Wi-Fi or Bluetooth, depending on the model.

DataView is available in the following languages: German, English, Chinese, Spanish, French, Italian, Dutch, Polish, Swedish, Czech and Turkish.

Do you have a question about using or installing your measurement equipment? Our support team is available to provide you with quick and effective solutions. Contact support for personalized assistance.


Contact support

References and accessories

To fully meet your expectations, a range of accessories is available that is compatible with your equipment. Feel free to add them to your quote request to obtain a complete and tailored solution.

CA 8345 Voltage Quality Analyser Class A

CA 8345 Voltage Quality Analyser Class A

P01160657N

CA8345 (4I/4U) graphical analyser of three-phase power, energy, harmonics and disturbances. IEC61000-4-30 Class A - EN50160 campaigns

picto

DataView Software

P01102095

PC software for configuring, saving and processing data, editing reports, etc. for Chauvin Arnoux measuring instruments

picto

Mains adapter

P01103076

PA32ER mains adaptor up to 1000V AC and DC to supply the voltage measurement channels of Qualistar2 CA8345 units

picto

PA40W-2 Power supply

P01102155

50VA mains adapter to power the Qualistar CA8345 and Scopix IV

picto

Connection adapter

P01103077

Adapter with C8 type input connector and output on 2 x 4 mm banana plugs, spaced 19 mm apart

picto

2-pole power cord - shaver socket

P01295174

2P mains power cord / shaver plug for power supply via a 2-pole socket

picto

Storage and carrying case

P01298083

Carrying case for Chauvin Arnoux Qualistar2 power quality analysers CA834x

picto

Memory card

P01103078

16 GB 30 MB/second Class 10 SD-HC memory card for Qualistar2 CA8345 units

picto

Mechanical accessories

P01103079

Magnetic hook for CA8345

picto

P01295531

picto

HX0122 Carrying accessory

HX0122

Adjustable carrying strap for SCOPIX IV oscilloscope

picto

Li-Ion pack charging support - CA 6116N, CA 6117

P01102130

Passive charging support Li-Ion battery pack for CA 6116N, CA 6117, requires mains adapter / type 2 charger P01102129 and requires mains lead P01295174

picto

Spare battery pack for CA 6116N-CA 6117

P01296047

Spare battery 5.8Ah for low-voltage installation controller CA 6116, CA 6117

picto

C193 AC current clamp

P01120323B

AC current clamp - Current range 1A to 1000A - Clamping diameter 52 mm - For Qualistar and PEL power loggers

picto

MN93 AC current clamp

P01120425B

AC current clamp - Current range 500mA to 200A - Clamping diameter 20 mm - For Qualistar and PEL power loggers

picto

MN93A AC current clamp

P01120434B

AC current clamp - 2 current ranges 5mA to 100A - 20 mm clamping diameter - For Qualistar and PEL power recorders

picto

E94 AC/DC current clamp

P01120044

AC-DC current clamp - Current range 100mA 100A - 2 ratings 10A and 100A - Clamping diameter 11.8 mm - For Qualistar2 and PEL power recorders

picto

PAC93 AC/DC current clamp

P01120079B

AC-DC current clamp - 1A to 1000A current range - 39 mm clamping diameter - For CA82xx - CA833x - CA 843x - PEL power loggers

picto

Mains adapter

P01101967

Mains adapter 230V 50/60 Hz European plug 2P for PAC series AC/DC current meters

picto

Current measurement accessory for Qualistar and PEL

P01101959

5A current adaptor for TI output 3-phase banana plugs for Qualistar QualistarPlus and Qualistar2 CA833x & CA834x and PEL

picto

Current measurement accessory for Qualistar and PEL

P01102131

ESSAILEC-type adapter box for current inputs for CA82xx - CA833x - CA843x - PEL10x - PEL11x power analysers and recorders

picto

J93 AC/DC current clamp

P01120110

AC-DC current clamp - Current range 50-3500 Aac - 50-5000 Adc for CA833x - CA843x - PEL10x

picto

A193-450 AmpFlex

P01120526B

Flexible AC current sensor - Current range 100mA to 10000A - Diameter 140mm - For Qualistar and PEL power loggers

picto

A193-800 AmpFlex

P01120531B

Flexible AC current transducer - Current range 100mA to 10000A - Diameter 250mm - For Qualistar and PEL power loggers

picto

MA194-250 MiniFlex

P01120593

Flexible AC current transducer - Current range 100mA to 10000A - Diameter 70mm - For Qualistar and PEL power loggers

picto

MA194-350 MiniFlex

P01120592

Flexible AC current sensor - Current range 100mA to 10000A - Diameter 100mm - For Qualistar and PEL power loggers

picto

MA194-1000 MiniFlex

P01120594

Flexible AC current transducer - Current range 100mA to 10000A - Diameter 300mm - For Qualistar and PEL power loggers

picto

Mechanical accessory

P01102149

Reeling Box storage accessory for tangle-free voltage cables. Integrated magnet for easy attachment to any metal surface.

picto

Test leads

P01295483

Set of 5 cords of 3m - Banana-Banana straight 4mm - 5 crocodile clips - set of colour-coded markers

picto

12V cigarette-lighter power supply converter

HX0061

Voltage converter from 10-60V DC 4A cigarette-lighter socket to 2P+T 120-150V DC 32W max female connector

picto

Mini94 AC current clamp

P01106194

AC amperometric clamp - Current range 50mA to 200A AC - Clamping diameter 16 mm - For Qualistar2 and PEL power recorders

picto
picto
picto
picto
picto
picto
picto
picto
picto
picto
picto
picto
picto
picto
picto
picto
picto
picto
picto
picto
picto
picto
picto
picto
picto
picto
picto
picto
picto
picto
CA 8345 Voltage Quality Analyser Class A

CA 8345 Voltage Quality Analyser Class A

P01160658N

CA8345 (4I/4U) graphical analyser of power, energy, harmonics and three-phase disturbances. IEC61000-4-30 Class A - Campaigns EN50160 - With mains adaptor for measurement channels

picto

E94 AC/DC current clamp

P01120044

AC-DC current clamp - Current range 100mA 100A - 2 ratings 10A and 100A - Clamping diameter 11.8 mm - For Qualistar2 and PEL power recorders

picto

DataView Software

P01102095

PC software for configuring, saving and processing data, editing reports, etc. for Chauvin Arnoux measuring instruments

picto

Mains adapter

P01103076

PA32ER mains adaptor up to 1000V AC and DC to supply the voltage measurement channels of Qualistar2 CA8345 units

picto

PA40W-2 Power supply

P01102155

50VA mains adapter to power the Qualistar CA8345 and Scopix IV

picto

Connection adapter

P01103077

Adapter with C8 type input connector and output on 2 x 4 mm banana plugs, spaced 19 mm apart

picto

2-pole power cord - shaver socket

P01295174

2P mains power cord / shaver plug for power supply via a 2-pole socket

picto

Storage and carrying case

P01298083

Carrying case for Chauvin Arnoux Qualistar2 power quality analysers CA834x

picto

Memory card

P01103078

16 GB 30 MB/second Class 10 SD-HC memory card for Qualistar2 CA8345 units

picto

Mechanical accessories

P01103079

Magnetic hook for CA8345

picto

P01295531

picto

HX0122 Carrying accessory

HX0122

Adjustable carrying strap for SCOPIX IV oscilloscope

picto

Li-Ion pack charging support - CA 6116N, CA 6117

P01102130

Passive charging support Li-Ion battery pack for CA 6116N, CA 6117, requires mains adapter / type 2 charger P01102129 and requires mains lead P01295174

picto

Spare battery pack for CA 6116N-CA 6117

P01296047

Spare battery 5.8Ah for low-voltage installation controller CA 6116, CA 6117

picto

C193 AC current clamp

P01120323B

AC current clamp - Current range 1A to 1000A - Clamping diameter 52 mm - For Qualistar and PEL power loggers

picto

MN93 AC current clamp

P01120425B

AC current clamp - Current range 500mA to 200A - Clamping diameter 20 mm - For Qualistar and PEL power loggers

picto

MN93A AC current clamp

P01120434B

AC current clamp - 2 current ranges 5mA to 100A - 20 mm clamping diameter - For Qualistar and PEL power recorders

picto

Mini94 AC current clamp

P01106194

AC amperometric clamp - Current range 50mA to 200A AC - Clamping diameter 16 mm - For Qualistar2 and PEL power recorders

picto

PAC93 AC/DC current clamp

P01120079B

AC-DC current clamp - 1A to 1000A current range - 39 mm clamping diameter - For CA82xx - CA833x - CA 843x - PEL power loggers

picto

Mains adapter

P01101967

Mains adapter 230V 50/60 Hz European plug 2P for PAC series AC/DC current meters

picto

Current measurement accessory for Qualistar and PEL

P01101959

5A current adaptor for TI output 3-phase banana plugs for Qualistar QualistarPlus and Qualistar2 CA833x & CA834x and PEL

picto

Current measurement accessory for Qualistar and PEL

P01102131

ESSAILEC-type adapter box for current inputs for CA82xx - CA833x - CA843x - PEL10x - PEL11x power analysers and recorders

picto

J93 AC/DC current clamp

P01120110

AC-DC current clamp - Current range 50-3500 Aac - 50-5000 Adc for CA833x - CA843x - PEL10x

picto

A193-450 AmpFlex

P01120526B

Flexible AC current sensor - Current range 100mA to 10000A - Diameter 140mm - For Qualistar and PEL power loggers

picto

A193-800 AmpFlex

P01120531B

Flexible AC current transducer - Current range 100mA to 10000A - Diameter 250mm - For Qualistar and PEL power loggers

picto

MA194-250 MiniFlex

P01120593

Flexible AC current transducer - Current range 100mA to 10000A - Diameter 70mm - For Qualistar and PEL power loggers

picto

MA194-350 MiniFlex

P01120592

Flexible AC current sensor - Current range 100mA to 10000A - Diameter 100mm - For Qualistar and PEL power loggers

picto

MA194-1000 MiniFlex

P01120594

Flexible AC current transducer - Current range 100mA to 10000A - Diameter 300mm - For Qualistar and PEL power loggers

picto

Mechanical accessory

P01102149

Reeling Box storage accessory for tangle-free voltage cables. Integrated magnet for easy attachment to any metal surface.

picto

Test leads

P01295483

Set of 5 cords of 3m - Banana-Banana straight 4mm - 5 crocodile clips - set of colour-coded markers

picto

12V cigarette-lighter power supply converter

HX0061

Voltage converter from 10-60V DC 4A cigarette-lighter socket to 2P+T 120-150V DC 32W max female connector

picto
picto
picto
picto
picto
picto
picto
picto
picto
picto
picto
picto
picto
picto
picto
picto
picto
picto
picto
picto
picto
picto
picto
picto
picto
picto
picto
picto
picto
picto

Add one or more products to your quote request in just a few clicks. Our teams will analyze your needs and get back to you quickly with a personalized offer tailored to your requirements.