CA 8436 Three-phase analyser Power Energy IP67
IP67 (4I/4U) graphical analyser of power, energy, harmonics and three-phase disturbances CA8436 - Campaigns EN50160
All the parameters simultaneously Designed for test and maintenance departments working in industrial or administrative buildings, the Qualistar+ CA 8331 can be used to obtain a snapshot of the main features characterizing the quality of the electrical network. Easy to handle and particularly compact, this instrument also offers a large number of calculated values and several processing functions. The CA 8331 is equipped with 3 voltage measurement channels and 3 current measurement channels. When the current sensors are connected to the C.A 8331, it recognizes them automatically. It also offers the possibility of mixing different types of current sensors and configuration of the ratios allows direct reading of the measurements. The Qualistar+ is specially designed for work in the field:
The multiple functions of the Qualistar+ CA 8331 make it particularly versatile. It is suitable for applications up to 1,000 V in CAT III and 600 V in CAT IV. The measurements obtained with the Qualistar models can be processed using two software tools: PAT2 delivered as standard and Dataview®, available as an option.
Reeling Box This practical magnetized winder equipped with the MultifFIX system allows you to adjust the length of your cables.
Technical specifications:
Electrical safety
Electrical safety
Software
Guarantee
Actual effective measurement
USB communication mode
Need information about our solutions? Our experts are available to advise and assist you with your project. Contact a sales representative now for a detailed presentation and an offer tailored to your needs.
Number of channels
3U / 4I
Number of inputs
4V / 3I
Voltage (TRMS AC+DC)
2 V to 1,000 V
Voltage ratio
up to 500 kV
C193
1 A to 1,000 Aac
AmpFLEX® or MiniFlex
100 mA to 10,000 Aac
PAC93
1 A to 1,300 Aac/dc
E3N/E27
50 mA to 100 Aac/dc
J93
50 A to 3,500 Aac / 50 A to 5,000 Adc
Current ratio
Up to 60 kA
Frequency
40 Hz to 69 Hz
Powers
W (P), VA (S), var (Q, N, D), PF, DPF, cos ϕ;, tan ϕ; 1
Energies
Wh, varh (Qh, Nh, Dh), VAh 1
Harmonics
yes
THD
Yes, from rank 0 to 50, phase
Flicker
Pst
Imbalance
Yes
Peak
Yes
Vector representation
Automatic
Display
TFT color screen ¼ VGA 320 x 240 diagonal 148 mm
Screen & curve capture
12
Electrical safety
IEC 61010 1,000 V CAT III / 600 V CAT IV
Protection index
IP53 / IK08
Languages
More than 27
Communication interface
USB
Autonomy
Up to 10 hours
Power supply
Rechargeable battery 9.6 V NiMH or mains power supply
Dimensions / Weight
240 x 180 x 55 mm / 1.9 kg
Language *
Do you have a question about using or installing your measurement equipment? Our support team is available to provide you with quick and effective solutions. Contact support for personalized assistance.
Language *
Do you have a question about using or installing your measurement equipment? Our support team is available to provide you with quick and effective solutions. Contact support for personalized assistance.
Language *
Do you have a question about using or installing your measurement equipment? Our support team is available to provide you with quick and effective solutions. Contact support for personalized assistance.
The PAT software allows you to control single-phase wattmeters and energy analysers, as well as clamp meters.
The PAT software is a tool that enables you to:
For the CA 8220/8230, CA 8332/32B/34/34B, CA 8335/8435 (embedded software versions v3.x) and F407/F607, use PAT. The main updates to PAT are:
The PAT 2 software enables you to control single-phase wattmeters and energy analysers, as well as clamp meters.
The PAT 2 software is a tool that enables you to:
For the CA 8331/33/36, CA 8436 and CA 8335 (embedded software version v4.x), use PAT 2. The main updates in PAT 2 are:
The devices covered are:
==> From version v4.x onwards
Some information on the devices’ other storage capacities (alarms, snapshots, etc.) is also displayed.
Download Microsoft .NET Framework 4, which is required to run the Trend Duration Calculator.
USB - Serial adapter ((USB-RS232)
Firmware for Qualistar Plus CA 8331, CA 8333, CA 8336 & CA 8436 network analysers.
To download the firmware, click on the link below and refer to the "read-me first.txt" file included. This firmware upgrade is compatible with all previous hardware versions.
Do you have a question about using or installing your measurement equipment? Our support team is available to provide you with quick and effective solutions. Contact support for personalized assistance.
To fully meet your expectations, a range of accessories is available that is compatible with your equipment. Feel free to add them to your quote request to obtain a complete and tailored solution.
P01160511
Graphic analyser of three-phase power, energy and harmonics (3I/3U) CA 8331
P01120434B
AC current clamp - 2 current ranges 5mA to 100A - 20 mm clamping diameter - For Qualistar and PEL power recorders
P01120425B
AC current clamp - Current range 500mA to 200A - Clamping diameter 20 mm - For Qualistar and PEL power loggers
P01120526B
Flexible AC current sensor - Current range 100mA to 10000A - Diameter 140mm - For Qualistar and PEL power loggers
P01120531B
Flexible AC current transducer - Current range 100mA to 10000A - Diameter 250mm - For Qualistar and PEL power loggers
P01120079B
AC-DC current clamp - 1A to 1000A current range - 39 mm clamping diameter - For CA82xx - CA833x - CA 843x - PEL power loggers
P01120323B
AC current clamp - Current range 1A to 1000A - Clamping diameter 52 mm - For Qualistar and PEL power loggers
P01101959
5A current adaptor for TI output 3-phase banana plugs for Qualistar QualistarPlus and Qualistar2 CA833x & CA834x and PEL
P01102131
ESSAILEC-type adapter box for current inputs for CA82xx - CA833x - CA843x - PEL10x - PEL11x power analysers and recorders
P01298055
Storage bag No21
P01298056
Carrying bag No22 to protect and store your equipment and associated accessories - 355 x 255 x 235 mm - QualistarPlus accessories
P01102095
PC software for configuring, saving and processing data, editing reports, etc. for Chauvin Arnoux measuring instruments
P01102059
Anti-scratch protective film for the screen of QualistarPlus CA8335 - CA8331 - CA8333 - CA8336 - CA8435 - CA8436 (spare)
P01102080
Set of plastic pins and rings in 12 colours to identify leads, current sensors and device inputs
P01102057
PA30W mains adaptor for powering QualistarPlus CA8331 - CA8333 - CA8335 - CA8336 - CA6116N and PEL115 (office use)
P01295293
Communication cable with USB type A connector to USB type B
P01103058Z
Set of 2 magnetic test points (for voltage measurement only) / Test point diameter: 6.6 mm / D4 mm angled female plug / 4 A / 1000 V CAT III - 600 V CAT IV
P01295476
Set of 4 x 3m cords - 4mm straight Banana-Banana - 4 crocodile clips - set of colour-coded marker pins
P01295483
Set of 5 cords of 3m - Banana-Banana straight 4mm - 5 crocodile clips - set of colour-coded markers
P01102081
Adapter for E3N and E27 current clamps for QualistarPlus series power analysers and PEL102 - 103 - 104 recorders
P01120110
AC-DC current clamp - Current range 50-3500 Aac - 50-5000 Adc for CA833x - CA843x - PEL10x
P01296024
Replacement rechargeable battery - 4 Ah Ni-MH technology - For QualistarPlus CA8335 - CA8331 - CA8333 - CA8336 - CA8435 - CA8436
P01102149
Reeling Box storage accessory for tangle-free voltage cables. Integrated magnet for easy attachment to any metal surface.
HX0061
Voltage converter from 10-60V DC 4A cigarette-lighter socket to 2P+T 120-150V DC 32W max female connector
P01102150
PA31ER mains adapter for powering QualistarPlus CA8335 - CA8331 - CA8333 - CA8336 voltage measurement channels.
HX0055B
9-pin USB-RS232 adapter for PC, Windows Vista/7/8/10 and MAC compatible, 1.8 m long, 1Mbps speed, RTS/CTS flow control
P01120592
Flexible AC current sensor - Current range 100mA to 10000A - Diameter 100mm - For Qualistar and PEL power loggers
P01120593
Flexible AC current transducer - Current range 100mA to 10000A - Diameter 70mm - For Qualistar and PEL power loggers
P01120594
Flexible AC current transducer - Current range 100mA to 10000A - Diameter 300mm - For Qualistar and PEL power loggers
P01120027
Isolated 100A AC/DC 100 kHz current probe for oscilloscope. Ø11.8 mm cable gland. Sensitivity 100-10 mV / 1A. Powered by battery or external 5V. 600V CAT III/300V CAT IV.
P01101967
Mains adapter 230V 50/60 Hz European plug 2P for PAC series AC/DC current meters
Add one or more products to your quote request in just a few clicks. Our teams will analyze your needs and get back to you quickly with a personalized offer tailored to your requirements.