Product presentation

F404T clamp meter with integrated Autocheck, safety for photovoltaic installations at your fingertips.

New F404T, for reliable and safe lockout of photovoltaic installations


Opening a live DC circuit causes a powerful and highly dangerous electric arc.

For economic reasons, the majority of systems used to disconnect or open the circuit in order to isolate the equipment are ‘live disconnectors’; this is the case, for example, with:

  • MC-type connectors
  • Most fuse boxes
  • Opening devices requiring a tool to be activated


To open or operate these devices safely, you must first ensure that the circuit is de-energised.

A faulty, malfunctioning or incorrectly configured device may incorrectly display "0.00 A DC".

This is not the case with the F404T, which features a patented Autocheck.

The F404T guarantees the reliability of DC Power-Off Verification

F404T: performance in everyday use

For electricians, the clamp meter is the ideal tool for any field work.

Easy to use, the F404T combines all the necessary features into a single, compact solution.

Ergonomic, the F404T is designed for one-handed use, even when wearing protective gloves.


For maximum efficiency, each measurement corresponds to a switch position; the ‘one button, one function’ concept and automatic AC or DC detection simplify its use.

Key features:

  • 1000 A AC / 1500 A DC
  • 1200 V AC / 1700 V DC
  • Dual 10,000-count backlit display
  • True RMS measurements
  • Automatic AC/DC detection for current and voltage
  • TrueInrush function for correct sizing of conductors and thermal protection
  • Automatic compensation for test lead resistance
  • Temperature measurement
  • Differential and RELative measurements
  • "Adapter" input for external probe
  • IP54
  • 1000 V CAT IV/1500 V CAT III
  • Supplied complete with test lead sets and accessories, temperature sensor, carrying case and battery
  • 2-year warranty
Electrical safety

Electrical safety

Electrical safety

Electrical safety

Protection class

Protection class

Actual effective measurement

Actual effective measurement

Load start measurement

Load start measurement

Need information about our solutions? Our experts are available to advise and assist you with your project. Contact a sales representative now for a detailed presentation and an offer tailored to your needs.


Contact a sales representative

Highlights

  • <\
  • Patented I self-monitoring function<\
  • Reliable and safe No-Current Verification <\/li><\
  • Suitable for use in all installations, at all voltages and in all low-voltage categories<\/li><\

Documentation and support

Do you have a question about using or installing your measurement equipment? Our support team is available to provide you with quick and effective solutions. Contact support for personalized assistance.


Contact support

Do you have a question about using or installing your measurement equipment? Our support team is available to provide you with quick and effective solutions. Contact support for personalized assistance.


Contact support

References and accessories

To fully meet your expectations, a range of accessories is available that is compatible with your equipment. Feel free to add them to your quote request to obtain a complete and tailored solution.

picto

P01120948B

F404T TRMS AC/DC photovoltaic clamp meter with patented autocheck

F404T TRMS AC/DC photovoltaic clamp meter with patented autocheck

P01120948

F404T TRMS photovoltaic clamp meter, Autocheck, 1000 A AC/1500 A DC, 1200 V AC/1700 V DC, ohms, continuity, diode, temperature. Supplied with carrying case and accessories. IP54 1000 V CAT IV/1500 V CAT III

picto

Storage and transport bag

P01298076

Bag with inside pocket, hand strap and MultiFix accessory. Usable interior dimensions 120 x 320 x 60 mm

picto

Test and measurement leads

P01295456Z

Set of 2 PVC touch point leads (1 red, 1 black) / Insulated Ø4mm angled male plug / 15A / 1.5 m / 1000V CAT IV

picto

Measuring and testing tip(s)

P01295454Z

Set of 2 moulded test probes (1 red / 1 black) for CAT III & IV 1000V installations

picto

Test and measurement leads

P01295455Z

Set of 2 PVC touch point leads (1 red, 1 black) / Ø4mm insulated straight male plug / 15A / 1.5 m / 1000V CAT IV

picto

Test and measurement leads

P01295453Z

Set of 2 moulded silicone leads (1 red, 1 black) / Ø4mm insulated straight male plug - Ø4mm insulated angled male plug / 15A / 1.5 m / 1000V CAT IV

picto

Measuring and testing tip(s)

P01295491Z

Ø2mm 1000V CAT IV 10A test probes. Suitable for IP2X contacts on modular switchboards. Ø4mm insulated female connector. Set of 2 (1 red/1 black). UL approved

picto

Measuring and test tip(s)

P01295458Z

Set of 2 4mm moulded touch-points (1 red and 1 black) for CAT 2 300V installations

picto

Measuring and testing tip(s)

P01295460Z

Set of 2 moulded touch-points 2mm (1 red and 1 black) for CAT 2 installations 300V

picto

Measurement and test accessory(ies)

P01295457Z

Set of 2 alligator clips (1 red and 1 black) 15A for CAT III & IV 1000V installations

picto

Measuring and testing accessories

P01295459Z

Accessory kit for electrician 2 moulded touch-points CAT IV, 2 moulded PVC cords (R/N) 1.5 m right male-male angled plug, 2 crocodile clips, 2 moulded touch-points D4 CAT II

picto

CA 753 Measuring adapter for 2P+T socket

P01191748Z

Measuring adapter for 2P+T EU and Schuko sockets. For safe P (Phase), N (Neutral) and PE (Earth) measurement with any test tip. Indicates P-N voltage (> 200 V) and phase position.

picto

Alkaline battery(ies)

P01296032

1.5 V cylindrical battery, LR03, AAA, RC03 format, alkaline technology, supplied individually

picto
picto
picto
picto
picto
picto
picto
picto
picto
picto
picto
picto

Add one or more products to your quote request in just a few clicks. Our teams will analyze your needs and get back to you quickly with a personalized offer tailored to your requirements.