MiniFlex MA19x for PEL and Qualistar
Flexible AC current transducer for Qualistar and PEL power loggers
POWER AND MOTOR MAINTENANCE ANALYSER
Add the energy function to your CA 8220
Firmly geared towards electrotechnics and the verification of rotating machinery, the CA 8220 is intended for companies' testing and maintenance teams. Equipped with a segmented liquid crystal display, compact and shock-resistant, its ergonomic human-machine interface makes it simple and pleasant to use because it is intuitive. The CA 8220 can be used to obtain a snapshot of the main characteristics of a single-phase or balanced three-phase network.
It also measures all the characteristics needed to check rotating machinery. It allows accurate measurements from a few millamperes to several kiloamperes, as required, by means of a wide range of sensors. Other features:
The CA 8220 is supplied with the PAT (Power Analyser Transfer) software for processing the measurements on a PC (display, analysis, etc). This software is available free of charge for download from our support website.
Electrical safety
Software
Protection class
Actual effective measurement
USB communication mode
Need information about our solutions? Our experts are available to advise and assist you with your project. Contact a sales representative now for a detailed presentation and an offer tailored to your needs.
Voltage (TRMS)
Phase/Phase: 660 Vac+dc Phase/Neutral: 600 Vac+dc
MN
MN93: 2 to 240 Aac; MN93A: 0.005 Aac to 5 Aac / 0.1 Aac to 120 Aac
AC
3 A to 1200 Aac
AmpFlex® or MiniFlex
30 A to 6500 Aac
PAC
10 A to 1000 Aac / 10 A to 1400 Adc
E3N/E27
50 mA to 10 Aac+dc, 100 mA to 100 Aac+dc
Frequency
40 Hz to 70 Hz
Other measurements
W (P), var (Q), PF, DPF, VA (S), temperature, phase rotation, 1 RPM, resistance, continuity, diode test, Wh, VAh, varh
Harmonics
Range 1 to 50
Sampling frequency
256 samples/period
Recording capacity
≥; 99 complete sets of voltage, current, power, and harmonic measurements
Power supply
6 batteries 1.5 V LR06, mains power supply optional
Autonomy
≥; 8 hours with display activated
Communication
Optical USB
Display
Backlit screen with 3 displays and symbols
Dimensions / Weight
211 x 108 x 60 mm / 0.88 kg
Electrical safety
IEC 61010 600 V CAT III, IP 54, pollution degree 2
Language *
Do you have a question about using or installing your measurement equipment? Our support team is available to provide you with quick and effective solutions. Contact support for personalized assistance.
Language *
Do you have a question about using or installing your measurement equipment? Our support team is available to provide you with quick and effective solutions. Contact support for personalized assistance.
Language *
Do you have a question about using or installing your measurement equipment? Our support team is available to provide you with quick and effective solutions. Contact support for personalized assistance.
The PAT software allows you to control single-phase wattmeters and energy analysers, as well as clamp meters.
The PAT software is a tool that enables you to:
For the CA 8220/8230, CA 8332/32B/34/34B, CA 8335/8435 (embedded software versions v3.x) and F407/F607, use PAT. The main updates to PAT are:
The PAT 2 software enables you to control single-phase wattmeters and energy analysers, as well as clamp meters.
The PAT 2 software is a tool that enables you to:
For the CA 8331/33/36, CA 8436 and CA 8335 (embedded software version v4.x), use PAT 2. The main updates in PAT 2 are:
USB - Serial adapter ((USB-RS232)
WARNING
If a previous version is already installed on the PC, you must uninstall it:
Compatible with the following devices:
METRIX multimeters:
METRIX HandScope:
CHAUVIN ARNOUX multimeter:
CHAUVIN ARNOUX HandScope:
V6.7.6:
V11.3.0:
The CA 8220 firmware can be updated by the user using the optical cable supplied with the device.
Please note: updating the firmware will erase all data (settings and photographs).
Back up any data you wish to keep to a PC using the dedicated software before updating the firmware.
To download the firmware, click the link below and refer to the "readme-first.txt" file included in the ZIP file.
Do you have a question about using or installing your measurement equipment? Our support team is available to provide you with quick and effective solutions. Contact support for personalized assistance.
To fully meet your expectations, a range of accessories is available that is compatible with your equipment. Feel free to add them to your quote request to obtain a complete and tailored solution.
P01160620
Single-phase power analyser - Measurement of harmonic power - Motor speed temperature
P01101959
5A current adaptor for TI output 3-phase banana plugs for Qualistar QualistarPlus and Qualistar2 CA833x & CA834x and PEL
P01295252
Optical to RS 232 cable - for CA 6470N and CA 6471 - also available in optical to USB version (see item code HX0056-Z)
P01298049
Bag No5 with 2 compartments, for hands-free use of CA 6522, CA 6524, CA 6526, CA 6528, CA 6532, CA 6534, CA 6536 insulation controllers
P01295288Z
Set of 2 PVC cords (1 red, 1 black) / Ø4mm insulated straight male plug - Ø4mm insulated straight male plug / 15A / 1.5 m / 600V CAT IV - 1000V CAT III
P01120079B
AC-DC current clamp - 1A to 1000A current range - 39 mm clamping diameter - For CA82xx - CA833x - CA 843x - PEL power loggers
P01120323B
AC current clamp - Current range 1A to 1000A - Clamping diameter 52 mm - For Qualistar and PEL power loggers
P01120425B
AC current clamp - Current range 500mA to 200A - Clamping diameter 20 mm - For Qualistar and PEL power loggers
P01120434B
AC current clamp - 2 current ranges 5mA to 100A - 20 mm clamping diameter - For Qualistar and PEL power recorders
P01120526B
Flexible AC current sensor - Current range 100mA to 10000A - Diameter 140mm - For Qualistar and PEL power loggers
P01120531B
Flexible AC current transducer - Current range 100mA to 10000A - Diameter 250mm - For Qualistar and PEL power loggers
P01102081
Adapter for E3N and E27 current clamps for QualistarPlus series power analysers and PEL102 - 103 - 104 recorders
P01102095
PC software for configuring, saving and processing data, editing reports, etc. for Chauvin Arnoux measuring instruments
HX0056-Z
Opto-isolated USB connection cable for CA 647x, CA 655x and Handscope, Windows compatible driver
HX0053
P01102131
ESSAILEC-type adapter box for current inputs for CA82xx - CA833x - CA843x - PEL10x - PEL11x power analysers and recorders
HX0055B
9-pin USB-RS232 adapter for PC, Windows Vista/7/8/10 and MAC compatible, 1.8 m long, 1Mbps speed, RTS/CTS flow control
P01120592
Flexible AC current sensor - Current range 100mA to 10000A - Diameter 100mm - For Qualistar and PEL power loggers
P01120593
Flexible AC current transducer - Current range 100mA to 10000A - Diameter 70mm - For Qualistar and PEL power loggers
P01120594
Flexible AC current transducer - Current range 100mA to 10000A - Diameter 300mm - For Qualistar and PEL power loggers
P01120027
Isolated 100A AC/DC 100 kHz current probe for oscilloscope. Ø11.8 mm cable gland. Sensitivity 100-10 mV / 1A. Powered by battery or external 5V. 600V CAT III/300V CAT IV.
P01101967
Mains adapter 230V 50/60 Hz European plug 2P for PAC series AC/DC current meters
HX0091
Pt100/Pt1000 probe adaptor for multimeter, 4 mm diameter insulated male plugs
P01160621
P01101959
5A current adaptor for TI output 3-phase banana plugs for Qualistar QualistarPlus and Qualistar2 CA833x & CA834x and PEL
P01295252
Optical to RS 232 cable - for CA 6470N and CA 6471 - also available in optical to USB version (see item code HX0056-Z)
P01298049
Bag No5 with 2 compartments, for hands-free use of CA 6522, CA 6524, CA 6526, CA 6528, CA 6532, CA 6534, CA 6536 insulation controllers
HX0053
P01295288Z
Set of 2 PVC cords (1 red, 1 black) / Ø4mm insulated straight male plug - Ø4mm insulated straight male plug / 15A / 1.5 m / 600V CAT IV - 1000V CAT III
P01120079B
AC-DC current clamp - 1A to 1000A current range - 39 mm clamping diameter - For CA82xx - CA833x - CA 843x - PEL power loggers
P01120323B
AC current clamp - Current range 1A to 1000A - Clamping diameter 52 mm - For Qualistar and PEL power loggers
P01120425B
AC current clamp - Current range 500mA to 200A - Clamping diameter 20 mm - For Qualistar and PEL power loggers
P01120434B
AC current clamp - 2 current ranges 5mA to 100A - 20 mm clamping diameter - For Qualistar and PEL power recorders
P01120526B
Flexible AC current sensor - Current range 100mA to 10000A - Diameter 140mm - For Qualistar and PEL power loggers
P01120531B
Flexible AC current transducer - Current range 100mA to 10000A - Diameter 250mm - For Qualistar and PEL power loggers
P01102081
Adapter for E3N and E27 current clamps for QualistarPlus series power analysers and PEL102 - 103 - 104 recorders
P01102095
PC software for configuring, saving and processing data, editing reports, etc. for Chauvin Arnoux measuring instruments
HX0056-Z
Opto-isolated USB connection cable for CA 647x, CA 655x and Handscope, Windows compatible driver
P01102131
ESSAILEC-type adapter box for current inputs for CA82xx - CA833x - CA843x - PEL10x - PEL11x power analysers and recorders
HX0055B
9-pin USB-RS232 adapter for PC, Windows Vista/7/8/10 and MAC compatible, 1.8 m long, 1Mbps speed, RTS/CTS flow control
P01120027
Isolated 100A AC/DC 100 kHz current probe for oscilloscope. Ø11.8 mm cable gland. Sensitivity 100-10 mV / 1A. Powered by battery or external 5V. 600V CAT III/300V CAT IV.
P01101967
Mains adapter 230V 50/60 Hz European plug 2P for PAC series AC/DC current meters
Add one or more products to your quote request in just a few clicks. Our teams will analyze your needs and get back to you quickly with a personalized offer tailored to your requirements.