MX604 Lightning arrester controller 50V/250V/500V
Analogue insulation tester - up to 2000MΩ at 50, 100 and 500V DC, lightning arrester test
The CA 6528 insulation tester is ideal for maintenance and repair operations on electrical equipment such as motors, cables, etc. Thanks to its "hands-free" bag, the CA 6528 insulation tester can be used without any constraints in the field. The shockproof sheath with stand (props) ensure stability on horizontal surfaces.
The large LCD screen can show the insulation value and the real test voltage simultaneously thanks to its double display. The backlighting makes it easy to read in all circumstances.
The CA 6528 megohmmeter measures resistance, insulation and continuity according to the applicable international standards: IEC 60364, NF C 15-100, VDE 100, etc. The continuity measurement integrates compensation of the cables. Insulation measurement is possible in manual mode, locked mode or programmed-duration mode with the timer. When measuring the voltage, an indicator shows the battery status.
The CA 6528 indicates the test results instantaneously: the screen turns red if the threshold is overrun.
The presence of a hazardous voltage (>30 V) is detected automatically by the CA 6528, which then prohibits insulation testing.
Technical specifications:
Voltage: 0 to 700 VAC/DC
Insulation: up to 11 GΩ
Continuity: 0.02 Ω to 40 Ω
Resistance: 1 Ω to 420 kΩ
Automatic voltage detection
Compliant with IEC 61557-1-2-4-10
Electrical safety: IEC 61010-1, 61010-2-030, 61010-2-034 - 600V CAT IV
IP40
Need information about our solutions? Our experts are available to advise and assist you with your project. Contact a sales representative now for a detailed presentation and an offer tailored to your needs.
Measurement range / resolution
± (1-700V) / 1V
Accuracy / input impedance
±1.2% L ± 1pt in AC+DC; ±1% L ± 1pt in DC / 25 MΩ
Frequency of use
DC; 45-65 Hz
Test voltage
250-500-1000 V
Range at maximum test voltage
11 GΩ
Measurement range 250 V
50 kΩ - 4.2 GΩ
500 V
100 kΩ - 4.2 GΩ
1000 V
200 kΩ - 11 GΩ
Measurement range / resolution
50 kΩ - 3.999 MΩ / 1kΩ; (0.2)1 3.6-39.99 MΩ / 10 kΩ; 36-399.9 MΩ / 100 kΩ; 360-4200 MΩ / 1 MΩ; (1kV) 3.6 - 11 GΩ / 10 MΩ
Accuracy
0.05-399.9 MΩ: ±1.5% L ± 10 pt 360-4000 MΩ: ±4% L ± 10pt; ±4% L ± 5 pt (under 1000V) 3.6-11 GΩ: ±10% L ± 10 pt
Timer (min:s)
10 s to 39 min 59 s
Alarms
1 threshold / test voltage
Measurement range
0.02 Ω - 40 Ω
Accuracy / Open circuit voltage
±1.2% L ±3 pt / 6 VDC < U < 9 VDC
Measurement current
≥; 200 mA (up to 2 Ω)
Continuity thresholds (Fast beep)
2 Ω / 1 Ω
Cable compensation
up to 5 Ω
Measurement range / resolution
1 -399.9 Ω / 0.1 Ω 360-3,999 Ω / 1 Ω 3.60-39.99 kΩ / 10 Ω 36.0-399.9 kΩ / 100Ω
Accuracy
±1.2% L ± 3 pt
Display
2 x 4000 pts
Power supply / Automatic shutdown
6 x LR 6 or AA batteries / 10 min disableable
Autonomy
1000 measurements: at 1 MΩ @ 1 kV (5 s ON / 25 s OFF); >3000 continuity measurements (5 s ON / 25 s OFF) at 1 Ω
Dimensions / Weight / IP rating
218 x 95 x 63 mm / 760 g / IP 40
EMC / Electrical safety
IEC 61326-1 / IEC 61010-1, IEC 61010-2-030 and IEC 61010-2-034 / 600V CAT IV
Compliance with standards
IEC 61557 parts 1, 2, 4 and 10
Language *
Do you have a question about using or installing your measurement equipment? Our support team is available to provide you with quick and effective solutions. Contact support for personalized assistance.
Language *
Do you have a question about using or installing your measurement equipment? Our support team is available to provide you with quick and effective solutions. Contact support for personalized assistance.
Language *
Do you have a question about using or installing your measurement equipment? Our support team is available to provide you with quick and effective solutions. Contact support for personalized assistance.
To fully meet your expectations, a range of accessories is available that is compatible with your equipment. Feel free to add them to your quote request to obtain a complete and tailored solution.
P01140838
Insulation tester 250V/500V/1kV;11GOhm - Manual, locked and timer mode. Voltage 700V AC+DC; Continuity. Resistance 420 kOhm; Visual alarm; 6 LR6 batteries; 218x95x63mm;IEC 61010;600V CAT IV
P01298049
Bag No5 with 2 compartments, for hands-free use of CA 6522, CA 6524, CA 6526, CA 6528, CA 6532, CA 6534, CA 6536 insulation controllers
P01295453Z
Set of 2 moulded silicone leads (1 red, 1 black) / Ø4mm insulated straight male plug - Ø4mm insulated angled male plug / 15A / 1.5 m / 1000V CAT IV
P01295454Z
Set of 2 moulded test probes (1 red / 1 black) for CAT III & IV 1000V installations
P01295457Z
Set of 2 alligator clips (1 red and 1 black) 15A for CAT III & IV 1000V installations
P01296033
1.5V cylindrical battery, LR6, AA, RC6 format, alkaline technology, supplied individually
P01102084A
Continuity probe / insulated female socket D4 mm / length 90 cm (3 x 30 cm) / protection 1000V max.
P01654246
Portable recording thermo-hygrometer for measuring temperature, relative humidity and dew point, with Bluetooth and USB interfaces.
P01654821
P01297104
Spare fuse 6x32, breaking current 200mA, 1000V, 10kA, HPF (supplied in quantities of 20)
Add one or more products to your quote request in just a few clicks. Our teams will analyze your needs and get back to you quickly with a personalized offer tailored to your requirements.